Curing Chamber
- Provide a constant temperature and humidity curing environment for the polar plate, promote the close combination of lead paste and plate grid, and improve the polar plate strength and electrochemical performance.
| Specifications | Parameters |
|---|---|
| Device Dimensions (mm) | (L×W×H) 4000 × 3600 × 4500 |
| Effective dimensions for the working chamber (plate placement area) | (L×W×H) 3100×3400×2900 |
| Control Range | Curing Stage: Room temperature to 65°C (adjustable), humidity 50–100% RH (adjustable) |
| Drying Stage: Room temperature to 85°C (adjustable), humidity ≤10% RH (adjustable) | |
| Control Precision |
Temperature – set value ±2°C; Humidity – set value ±5% RH |
| Power Parameters | Air source pressure ≥ 0.45 MPa |
| Water pressure (pure or softened water) ≥ 0.2 MPa | |
| Power supply: AC 380 V/AC 220 V, 50 Hz | |
| Total power per unit: 86 kW (including 75 kW for electric heating and 11 kW for fans) |